Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 157 items found.

  • Duplex Double Test Insertion/Return Loss Test Station

    JW8302 - Shanghai Joinwit optoelectronic Tech,co.,Ltd

    JW8302 Duplex double test Insertion/Return Loss Test Station is a professional equipment to test CWDM device, multi-wavelength device, PLC, fiber optical patch cord and other passive optical devices. It is a new-generation precision optical instrument of JOINWIT who combined with so many years  experience in optical passive detection. It equipped with VFL or 850 light source , supporting threshold determination, automatic multi-wavelength detection, system integration, secondary development, upper computer solution, etc. Double LC interface or other different interfaces can be tested simultaneously which is convenient for testing and improves efficiency; The  VFL function could automatic on and off, no need to replace the connector.

  • Modulation Distortion For E5081A Up To 20 GHz

    S960704B - Keysight Technologies

    The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.

  • Optical Signal Test Set

    OST - Spectronix

    The Optical Signal Test Set (OSTS) combines a state of the art optical power meter, a variable attenuator, and a high stability laser source.  The unit is able to measure optical signals below -100dBm with 0.001dB resolution at a fraction of the size, power, and cost of competing solutions.   Other features include data logging, programmable filtering, and auto calibration.  Its small shielded ruggedized package, USB/power interface, and low cost make this unit perfect for lab use or for integration into larger systems.

  • ARINC 429 Bus Interfaces

    AIM GmbH

    AIM’s  > ARINC 429 test, simulation, monitoring and analysis modules use our field proven Common Core hardware design giving you the best performance, best feature set and highest functional integration on the market. The use of SoC (System on Chip) based core designs with multiple processors for real time bus protocol and application support, massive memory and IRIG-B time code encoder/decoder functions are standard. The latest versions also support avionics discrete I/O.

  • AFDX®/ARINC664P7 Modules

    AIM GmbH

    AIM’s AFDX®/ARINC664P7 test, simulation, monitoring and analysis modules use our field proven Common Core hardware design giving you the best performance, best feature set and highest functional integration on the market. The use of SoC (System on Chip) based core designs with multiple processors for real time bus protocol and application support, massive memory and IRIG-B time code encoder/decoder functions are standard. Versions are available to support the Boeing specific ARINC664P7 extensions.

  • DC Power Supply

    Chroma ATE Inc.

    DC power supplies offer many unique advantages for telecom, automated test system & integration, industrial, battery charge & simulation for hybrid cars and solar panel simulation. These advantages include high power density of 15KW in 3U, precision readback of output current and voltage, output trigger signals as well as the ability to create complex DC transient waveforms to test device behavior for spikes, drops, and other voltage deviations.

  • Saluki S87234 Series USB Peak and Average Power Sensor (max. 67GHz)

    Saluki Technology Inc.

    S87234D/E/F/L USB peak and average power sensor is a diode-detection broadband power measurement instrument based on the USB 2.0 interface, which can realize accurate average power measurement, pulse power measurement with large dynamic range and CCDF statistical measurement analysis. The frequency range covers 50MHz to 67GHz, the highest power accuracy can reach 0.2dB, the video bandwidth is ≥30MHz, and the rise/fall time is ≤13ns.S87234 series can flexibly expand the power measurement function of electronic measuring instruments and test systems, and is mainly used for field testing, production line testing and system integration.

  • Modulation Distortion Up To 53 GHz

    S95070B - Keysight Technologies

    S95070B software enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 53 GHz. The wide dynamic range and vector error correction of the PXI VNA results in an extremely low residual EVM from the test setup, giving you a complete picture of your device’s performance without test system interference. S95070B software measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals through spectral correlation between the input and output spectrum, without doing demodulation. Integration with the PXI VNA’s measurement flexibility enables you to do quick modulation distortion measurements along with traditional VNA tests.

  • Modulation Distortion Up To 70 GHz

    S930707B - Keysight Technologies

    S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 8.5 GHz

    S930700B - Keysight Technologies

    S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 26.5 GHz

    S930702B - Keysight Technologies

    S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 50 GHz

    S930705B - Keysight Technologies

    S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 90 GHz

    S930709B - Keysight Technologies

    S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 13.5 GHz

    S930701B - Keysight Technologies

    S930701B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 13.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930701B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 125 GHz

    S930712B - Keysight Technologies

    S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

Get Help